SEWAGE TREATMENT

Biocycle unit equivalent : The Tricel Novo

OVERVIEW

Tricel Novo is the biocycle unit alternative wastewater treatment plant system. This system is long-lasting, efficient, robust, simple to use, and easy to install. If you would like to talk directly to our technical and sales team about this solution, contact us.

What is the Tricel biocycle alternative and how does it works?

When talking about Biocycle unit we refer to wastewater treatment plants. The Tricel biocycle version is called Tricel Novo. Tested in compliance with EN12566-3 CE Certification, Tricel Novo plants provide a simple and affordable solution with high-quality wastewater treatment. It also ensures compliance with these environmental protection regulations.

Table of Contents

+35 364 6655615

If you have any questions, feel free to call us

Share on Facebook
Share on LinkedIn

vISIT OUR virtual SHOWROOM

How does the biocycle unit by Tricel works?

Tricel Novo has a 3 steps process

Stage 1: the primary settlement chamber

On the first stage of wastewater treatment, the grease and the mud will be separated from the water. The grease will stay on the surface and the mud will go to the bottom of the tank.

Stage 2: the aeration chamber

In this compartment, the wastewater treatment involves aerobic breakdown. Masses of naturally occurring bacteria inhabit specially designed filter media.

The aerobic bacterias are going to digest the pollution from the wastewater. These bacteria are sustained with air, which is continuously supplied from a purpose-built pump in the unit’s top section.

Stage 3: final settlement chamber

In the third stage of wastewater treatment, the suspended sludge containing bacteria is carried with the liquid into the settlement chamber and settles to the bottom of the chamber.

From there, a continuous sludge return system pumps it back to the primary settlement chamber. The remaining treated liquid now meets the required standard to be safely passed out of the Tricel system.

Features and Benefits of the Tricel wastewater treatment plant

  • Compression moulded SMC tank. SMC is exceptional in the wastewater treatment industry, with Tricel SMC tanks operating in some of the harshest climatic conditions for over 50 years with no defects.
  • Components are manufactured under heat and high pressure and have unparalleled strength and toughness over standard GRP tanks or PE tanks.
  • Tricel’s ceramic diffuser is a first in the domestic wastewater treatment industry and will last twice as long as all standard competitors’ rubber equivalents. This saves money in both call-out fees and replacement parts.
  • No concrete backfill for installation on most sites, saving up to €400 over lower quality GRP/plastic competitors.
  • No moving parts or pumps in the plant, ensuring consistent operation and minimal maintenance and repair costs.
  • Tricel Novo plants are designed with a shallow invert to reduce both installation and time costs.

The size of your Tricel Novo unit

This part is one of the most important as the right sizing goes hand in hand with the efficiency of the treatment. If the domestic wastewater treatment system is not sized correctly, the effluent can pollute the local environment. Such issues result in damaged wells or water sources and cause problems for public health.

 

How to determine the size of your system?

 

The common metric used to calculate the size of a residential wastewater treatment solution is the Population Equivalent or PE. According to the definition of the OECD:

Population equivalent (in waste-water monitoring and treatment) refers to the amount of oxygen—demanding substances whose oxygen consumption during biodegradation equals the average oxygen demand of the waste water produced by one person. For practical calculations, it is assumed that one unit equals 54 grams of BOD per 24 hours

In order to know the PE range you need for your residential wastewater treatment system, you will need to count the number of bedrooms in the house. The table below gives you an idea of it:

Number of bedrooms
Population equivalent
2
4
3
5
4
6
5
7
6
8
7
9
8
10

Tricel Novo Range

Design Population
IE6
IE6+
IE8
IE10
IE12
IE18
IE24
IE30
IE36
IE42
IE50
Number of people
1-6
2-6
2-8
3-10
4-12
6-18
8-24
10-30
12-36
14-42
16-50

Dimensions of the Tricel Novo

Novo IE6

Tricel Novo IE6

No of people: 1-6

Length: 2.10m

Width: 1.64m

Height: 2.24m

Air blower rating: 60 watts

Novo IE12

Tricel Novo IE12

No of people: 4-12

Length: 3.60m

Width: 1.64m

Height: 2.27m

Air blower rating: 100 watts

Tricel Novo IE36

Tricel Novo IE36

No of people: 12-36

Length: 3.60m

Width: 1.64m

Height: 1.99m

Length: 5.60m

Width: 1.64m

Height: 2.27m

Air blower rating: 200 watts + 800 watts

Novo IE6+

Tricel Novo IE6+

No of people: 2-6

Length: 2.60m

Width: 1.64m

Height: 2.24m

Air blower rating: 60 watts

Novo IE18

Tricel Novo IE18

No of people: 6-18

Length: 4.60m

Width: 1.64m

Height: 2.27m

Air blower rating: 200 watts

Tricel Novo IE42

Tricel Novo IE42

No of people: 14-42

Length: 5.60m

Width: 1.64m

Height: 2.27m

Length: 5.60m

Width: 1.64m

Height: 2.27m

Air blower rating: 200 watts x 2

Novo IE8

Tricel Novo IE8

No of people: 2-8

Length: 2.60m

Width: 1.64m

Height: 2.24m

Air blower rating: 80 watts

Tricel Novo IE24

No of people: 8-24

Length: 6.60m

Width: 1.64m

Height: 2.27m

Air blower rating: 200 watts

Tricel Novo IE50

Tricel Novo IE50

No of people: 16-50

Length: 6.60m

Width: 1.64m

Height: 2.27m

Length: 6.60m

Width: 1.64m

Height: 2.27m

Air blower rating: 200 +120 + 80 watts

Novo IE12

Tricel Novo IE10

No of people: 3-10

Length: 3.10m

Width: 1.64m

Height: 2.24m

Air blower rating: 80 watts

Tricel Novo IE30

No of people: 10-30

Length: 2.60m

Width: 1.64m

Height: 1.99m

Length: 5.60m

Width: 1.64m

Height: 2.27m

Air blower rating: 200 watts + 800 watts

IE Gravity Outlet

Up to 6PE domestic gravity flow outlet.

Tricel Novo IE6 Gravity Outlet drawing

IE Pumped Outlet

1-6 domestic pumped unit. Suitable for pumping to a raised discharge area (over).

Tricel Novo IR6 Pumped Outlet drawing

Tricel Novo: Key features & benefits

 

The compression moulding process is one of the most technologically advanced features available on the market. Components are manufactured under heat and high pressure. They have a competitive strength and durability over standard GRP tanks or PE tanks.

SMC is a unique material in the sewage treatment industry with Tricel SMC tanks operating in some of the harshest climatic conditions for over 50 years with no defects.

Tricel’s ceramic diffuser will last twice as long as all standard competitors rubber equivalents. It is a cost-saver in both call out fees and replacement parts.

No concrete backfill for installation on most sites which allows you to save up to €400 over lower quality GRP/plastic competitors.

There are no moving parts or pumps in the plant which is ensuring reliable operation during the treatment process and minimal running costs.

Tricel Novo plants are designed with a shallow invert to limit both installation and time costs.

Our range of products

Tricel Septic tank

Tricel Vento Septic Tank

Shallow dig tank, strong & robust underground tank, No electrical or moving parts. Ideal for sites with good drainage & plenty of space.

Learn more
Tricel Novo Domestic-Sewage-Treatment-System

Tricel Novo Sewage Treatment Plant

Durable & long lasting SMC tank, shallow dig tank, easy installation (Plug and Play), long life components.

Learn more
Tricel-Commercial-Sewage-Treatment-System

Tricel Maxus Sewage Treatment Plant

Commercial plant. Submerged Aerated Filter (SAF) technology. Ideal for every project over 50 Population Equivalent.

Learn more
Tertiary treatment of wastewater

Tricel Tero Tertiary Treatment

An eco-friendly and modular system with proven E.Coli Treatment capabilities in line with the new EPA requirements.

Learn more
Tricel Packaged Filter System Puraflo

Tricel Puraflo Secondary treatment plant

Ideal for sensitive sites, compliant to Irish Standard, small footprint.

Learn more
Tricel Sandcel product

Tricel Sandcel
Sand Polishing Filter

Provides a dual function of polishing the effluent from a wastewater treatment system and disposing it into groundwater.

Learn more
Sewage Pumping Solutions

Tricel Pumping Stations

Pump fluids from one place to another where gravity drainage cannot be used, easy and trouble-free installation

Learn more

50 YEARS IN BUSINESS

A highly successful multinational corporation with over 50 years’ valuable industry experience

SEWAGE TREATMENT PLANTS

Plants available for all capacities, from 1PE up to 50PE. Free advice on request.

Fast Delivery

On-time delivery is a core requirement of our successful business operations

Meet our team

To find a technician in your area, visit our page

TALK SEWAGE TREATMENT

To speak to one of our agents online, click here

ASK FOR A QUOTE

Request a free quote today to have a quote that meets your project!

Key Features

Fast delivery

RELIABLE & LONG-LASTING

SMC tank, strong & lightweight

High quality icon

FAST DELIVERY

Tricel Products are certified to EN12566-1 and EN 12566-3 certified

Technical expertise

CERTIFIED

CE certification EN12566- 3, EN12566-1 and S.R.66

Frequently Asked Questions

PE represents the initials of Population Equivalent. Population equivalent: conversion value which aims at expressing non-domestic applications in terms of domestic loading based on 1 person creates 60 g/day BOD5 and 150l/day. (Code of Practice: Wastewater Treatment and Disposal Systems Serving Single Houses (p.e. < 10), EPA)

Tricel Novo Vitae

 Both are wastewater treament plant solutions manufactured by Tricel. Wastewater treatment plants offer a superior quality of treatment. For example, the Tricel Novo comprises of three independent wastewater treatment zones and offers an average of efficiency of 95.9% BOD removal.
This is a higher treatment standard than the effluent from a septic tank. Please note: all wastewater treatment plants used in Ireland must comply with the EN12566-3 standard and all septic tanks must comply with the EN12566-1 standard..

Tricel Vento

The septic tank from Tricel is manufactured as a primary treatment. Designed for the settlement of your effluent. This product may need an additional treatment like the Sandcel or Puraflo.

Most Tricel products have a warranty. To discover all the guarantees on our products, as well as on the internal parts, consult our dedicated product pages.

The required standards are 20:30:20 BOD, SS, NH4. All Tricel produces exceed the requirements when tested to En12566-3 and comply with SR66.

Learn more about our certification

Tricel recommends that you maintain your device to the fullest. You are obliged by law to avoid all types of pollution or nuisances. Do not hesitate to contact us for more information on our service contracts. An annual maintenance contract may be offered.

Get in touch