If you have a house that is not connected to the main sewage system, you must installed an individual sewage treatment system.
Below what’s included in this article.
Table of Contents
Wastewater Treatment Plant advice – What are the treatment levels?
Primary treatment: wastewater originating from the house (including toilets, sinks, and showers) flows into the tank.
In a sewage treatment plant, the effluent enters the primary settling chamber. Within this chamber, settlement takes place as heavier solids precipitate out of the wastewater, forming sludge at the tank’s bottom, while lighter solids rise to form a scum layer on the water’s surface.
Primary treatment is the only treatment phase in a septic tank. With a wastewater treatment plant, it occurs in the 1st chamber (the primary chamber).
Secondary Treatment: in a wastewater treatment plant, following the primary settling chamber is the aeration chamber.
It houses abundant naturally occurring bacteria thriving on specially designed filter media. These bacteria feed on the waste, extracting it from the effluent. A continuous air supply from a low-pressure, high-volume compressor located in the top section of the unit supports these bacteria. Wastewater repeatedly flows through the filter media, ensuring exceptionally high treatment efficiency.
Tertiary treatment: Tertiary treatment additional treatment processes which result in further purification than that obtained by applying the primary and secondary treatment. This is the last treatment, it is applied, if for special cases, additional treatment is necessary.
In summary:
- Septic tanks provide primary treatment only.
- Wastewater treatment plants offer secondary treatment.
- Combining a septic tank with a sand polishing filter or packaged filter system results in secondary treatment.
- Pairing a wastewater treatment plant with a sand polishing filter or packaged filter system yields tertiary treatment.
How does a Tricel Novo Wastewater Treatment Plant work?
Watch our dedicated video.
See below the treatment stages inside a Tricel Novo.
- The wastewater enters the plant.
- Heavier solids settles at the bottom and create sludge. Lighter solids floats to the top to create the scum.
- The aeration chamber where a constant supply of air (from a compressor located under the top lid) sustains naturally occurring bacteria who feed on the waste, removing it from the effluent.
- The clarification chamber or final settlement chamber. Any remaining tiny bacterial particles separate from the liquid before it exits the plant. This decelerates the liquid flow, enabling the last traces of impurities to settle at the tank’s bottom. A sludge return system then sends these impurities back to the primary settlement chamber.
Sizing a Wastewater Treatment Plant
In order to calculate the proper size for your sewage treatment installation, we will use the Population Equivalent metric.
This metric is calculated with the number of bedrooms in your house.
Wastewater treatment advice, please find below the table:
Number of bedrooms | Population Equivalent (PE) |
---|---|
2 | 4 |
3 | 5 |
4 | 6 |
5 | 7 |
6 | 8 |
7 | 9 |
8 | 10 |
Tricel wastewater treatment solutions
Tricel offers a wide range of sewage treatment products.
From septic tanks to wastewater treatment plants. We have a set of products, ideal for any domestic sewage need. Please see below for a list of our available products, with the corresponding sizes.
Size in PE | Tricel Novo (wwtp) | Tricel Vitae (NI only) | Tricel Vento (septic tank) |
---|---|---|---|
1-6 | IE6 or IE6+ | UK 6 | Vento 6 |
7-10 | IE8 or IE10 | UK 9 | Vento 12 |
11-12 | IE12 | UK 12 | Vento 12 |
13-18 | IE18 | UK 15 | Vento 20 |
18-24 | IE24 | UK 20 | Vento 20 |
We also have solutions available for secondary and tertiary treatment. This is the case of the Tricel Puraflo, Tricel Tero and the Sandcel sand polishing filter.
Once again, for any further information, do not hesitate to contact us.
The process of getting a sewage treatment system
To obtain a free quote from our website, simply fill out one of the contact forms. Your request will then be dispatched and processed as soon as possible by one of our local representative.
Once the request is received, our local technician will take care of you. To answer your request as best as possible, he will contact you quickly. Why?
- To discuss your project. Is it a new build or an upgrade? Has a site assessment been conducted? What are the recommendations?
- To qualify the urgency of your wastewater treatment project.
Based on your discussion with our team, we’ll be able to advice, quote or come and do a free site visit. This will allow you to gain visibility on the project and will provide the most appropriate services & products.
The visit of our local technician is essential in case of complex projects and if you also want an estimate with groundwork.
This visit will also be an opportunity for you to meet the your local Tricel representative. A person who will accompany you throughout your project including after installation for the maintenance of your system.
Articles you might be interested in
Our range of products
Tricel Vento Septic Tank
Shallow dig tank, strong & robust underground tank, No electrical or moving parts. Ideal for sites with good drainage & plenty of space.
Tricel Novo Sewage Treatment Plant
Durable & long lasting SMC tank, shallow dig tank, easy installation (Plug and Play), long life components.
Tricel Maxus Sewage Treatment Plant
Commercial plant. Submerged Aerated Filter (SAF) technology. Ideal for project over 50 PE.
Tricel Tero Tertiary Treatment
An eco-friendly and modular system with proven E.Coli Treatment capabilities in line with the new EPA requirements.
Tricel Puraflo Secondary treatment plant
Ideal for sensitive sites, compliant to Irish Standard, small footprint.
Tricel Sandcel
Sand Polishing Filter
Provides a dual function of polishing the effluent from a wastewater treatment system and disposing it into groundwater.
Tricel Pumping Stations
Pump fluids from one place to another where gravity drainage cannot be used, easy and trouble-free installation
50 years in business
A highly successful multinational corporation with over 50 years’ valuable industry experience
SEWAGE TREATMENT PLANTS
Plants available for all capacities, from 1PE up to 50PE. Free advice on request.
Fast Delivery
On-time delivery is a core requirement of our successful business operations
Meet our team
To find a technician in your area, visit our page
TALK SEWAGE TREATMENT
To speak to one of our agents online, click here
ASK FOR A QUOTE
Request a free quote today to have a quote that meets your project!
Frequently Asked Questions
WHAT IS PE ?
PE represents the initials of Population Equivalent. Population equivalent: conversion value which aims at expressing non-domestic applications in terms of domestic loading based on 1 person creates 60 g/day BOD5 and 150l/day. (Code of Practice: Wastewater Treatment and Disposal Systems Serving Single Houses (p.e. < 10), EPA)
DIFFERENT PRODUCTS SOLD BY TRICEL
Tricel Novo & Vitae
Both are wastewater treament plant solutions manufactured by Tricel. Wastewater treatment plants offer a superior quality of treatment. For example, the Tricel Novo comprises of three independent wastewater treatment zones and offers an average of efficiency of 95.9% BOD removal.
This is a higher treatment standard than the effluent from a septic tank. Please note: all wastewater treatment plants used in Ireland must comply with the EN12566-3 standard and all septic tanks must comply with the EN12566-1 standard..
Tricel Vento
The septic tank from Tricel is manufactured as a primary treatment. Designed for the settlement of your effluent. This product may need an additional treatment like the Sandcel or Puraflo.
WARRANTIES
Most Tricel products have a warranty. To discover all the guarantees on our products, as well as on the internal parts, consult our dedicated product pages.
WHAT IS THE QUALITY OF THE WASTEWATER PRODUCED?
The required standards are 20:30:20 BOD, SS, NH4. All Tricel produces exceed the requirements when tested to En12566-3 and comply with SR66.
Learn more about our certification
MAINTENANCE ON THE WASTEWATER TREATMENT SYSTEMS
Tricel recommends that you maintain your device to the fullest. You are obliged by law to avoid all types of pollution or nuisances. Do not hesitate to contact us for more information on our service contracts. An annual maintenance contract may be offered.