Properly installed, operated and maintained plants will give many years of trouble free service.
All Novo plants are fitted with an alarm, if there is a fault in the air blower or discharge pump – a buzzer will alert. The buzzer can be muted until the problem is fixed. Once fixed, the alarm will reset automatically and the mute switch must be turned on. All electrical work should be carried out by a qualified person.
If you have any questions, feel free to call us
VISIT OUR virtual SHOWROOM
Regular Maintenance
Regular maintenance of your product will ensure its longevity. Please see below the different elements that need to be checked regularly:
- The vent around the blower base. All vents should be checked to make sure they are not blocked or obstructed.
- The vent under the desludging cover allows gas to escape and stops the tank from becoming pressurized.
- Check if the air blower is working (listen to the “hum”) when you are standing by the plant.
- The inlet and outlet should be checked to remove anything that would block the flow.
- When do you need to check your wastewater treatment system? At least once per year. An annual maintenance will help prevent any unexpected issues with your system.
Troubleshooting plant operation
- Blower/pump won’t start or run.
- Blower operates but delivers no air.
- Plant fills above the working water level.
- Pump operates but delivers no water.
- Blowers runs intermittently.
- Pump runs intermittently.
- The alarm is sounding, but the pump and blower are working.
Troubleshooting your wastewater treatment plant
Always confirm the actual source of the odour before proceeding with any corrective measures.
Check if the odour is coming from another outside source such as a storm drain.
All wastewater disposal plants vent gases back through soil pipes and out roof vents. Improperly installed roof vents can cause odour problems.
Traps/U-bends in drains prevent odours from entering the home. To function they must contain water and be sealed correctly.
Examples of troubleshooting
At Tricel, we prioritise our customers’ needs and offer support from the start of the project through to product delivery, installation, and throughout the lifespan of the Tricel Novo Wastewater Treatment System.
If you experience any issues with your Tricel Novo, simply give us a call and we’ll be here to assist you.
The troubleshooting process is pretty simple. Please find below an example of an intervention provided by a Tricel technician.
Our customer contacted us for troubleshooting with his Tricel Novo system, which was installed three years ago. He reported that the alarm on his wastewater treatment plant was beeping. A Tricel technician promptly visited his home to address the issue.
Upon arrival, the technician quickly identified the problem: there was an issue with the compressor. Upon inspecting the plant, he noticed that the lid was surrounded by overgrown grass and leaves. The long grass had accumulated around the lid, blocking air flow and choking the compressor, which subsequently burned out, disrupting the oxygen supply for the bacteria.
The technician replaced the compressor in just a few minutes and checked the wastewater treatment plant to ensure it was functioning properly. No further issues were found, and the plant was operating as expected.
He explained the cause of the malfunction to the owner and advised him to keep the grass around the plant trimmed short to avoid future problems. This guidance should help prolong the life of the new compressor.
Tricel offers high-quality wastewater treatment plants and has years of expertise and supplying reliable components. The compressors supplied with Tricel Novo systems are designed to provide trouble-free operation for years, as long as the guidelines are followed and the plant is well-maintained.
The owner installed a Tricel Novo 6 PE system six years ago. Tricel Novo wastewater treatment plants ensure compliance with environmental protection regulations while offering a straightforward, cost-effective solution.
The tank was full because the blower wasn’t functioning properly.
The effluent flows into the primary settlement chamber, where heavier solids settle to the bottom of the tank to form sludge, while lighter solids float to the top to create a scum layer. This top layer acts as a seal to contain odors. The chamber removes up to 70% of the solids present. Next, the effluent proceeds to the aeration chamber, where naturally occurring bacteria thrive on specially designed plastic filter media, breaking down the waste in the liquid. A continuous air supply from a low-pressure, high-volume compressor sustains these bacteria, maximizing treatment efficiency as the wastewater moves through the filter media.
From there, the wastewater moves to the final settlement chamber, where any remaining fine bacterial particles separate from the liquid before being discharged. This process slows down the liquid’s velocity, allowing any remaining trace impurities to settle at the bottom of the tank. These impurities are then redirected back to the primary settlement chamber through a sludge return system.
Due to blower issues, solids flowed into the second and third chambers, causing odor issues around the system.
During the annual maintenance visit, the technician inspected the three chambers of the Tricel Novo and replaced the compressor to ensure the system was functioning correctly. No further issues were detected, and the plant was operating as it should.
Articles you might be interested in
Our range of products
Tricel Vento Septic Tank
Shallow dig tank, strong & robust underground tank, No electrical or moving parts. Ideal for sites with good drainage & plenty of space.
Tricel Novo Sewage Treatment Plant
Durable & long lasting SMC tank, shallow dig tank, easy installation (Plug and Play), long life components.
Tricel Maxus Sewage Treatment Plant
Commercial plant. Submerged Aerated Filter (SAF) technology. Ideal for project over 50 PE.
Tricel Tero Tertiary Treatment
An eco-friendly and modular system with proven E.Coli Treatment capabilities in line with the new EPA requirements.
Tricel Puraflo Secondary treatment plant
Ideal for sensitive sites, compliant to Irish Standard, small footprint.
Tricel Sandcel
Sand Polishing Filter
Provides a dual function of polishing the effluent from a wastewater treatment system and disposing it into groundwater.
Tricel Pumping Stations
Pump fluids from one place to another where gravity drainage cannot be used, easy and trouble-free installation
50 years in business
A highly successful multinational corporation with over 50 years’ valuable industry experience
SEWAGE TREATMENT PLANTS
Plants available for all capacities, from 1PE up to 50PE. Free advice on request.
Fast Delivery
On-time delivery is a core requirement of our successful business operations
Meet our team
To find a technician in your area, visit our page
TALK SEWAGE TREATMENT
To speak to one of our agents online, click here
ASK FOR A QUOTE
Request a free quote today to have a quote that meets your project!
Key features
Cost-Effective
Operating costs are reduced to
a minimum
quality
Sewage treatment plants are extremely reliable and durable as they are made out of long-lasting materials (20 to 40 years)
Certified
All Tricel Novo sewage treatment plants are tested to the highest quality standards and are EU Certified to EN12566-3
Frequently Asked Questions
WHAT IS PE ?
PE represents the initials of Population Equivalent. Population equivalent: conversion value which aims at expressing non-domestic applications in terms of domestic loading based on 1 person creates 60 g/day BOD5 and 150l/day. (Code of Practice: Wastewater Treatment and Disposal Systems Serving Single Houses (p.e. < 10), EPA)
DIFFERENT PRODUCTS SOLD BY TRICEL
Tricel Novo & Vitae
Both are wastewater treament plant solutions manufactured by Tricel. Wastewater treatment plants offer a superior quality of treatment. For example, the Tricel Novo comprises of three independent wastewater treatment zones and offers an average of efficiency of 95.9% BOD removal.
This is a higher treatment standard than the effluent from a septic tank. Please note: all wastewater treatment plants used in Ireland must comply with the EN12566-3 standard and all septic tanks must comply with the EN12566-1 standard..
Tricel Vento
The septic tank from Tricel is manufactured as a primary treatment. Designed for the settlement of your effluent. This product may need an additional treatment like the Sandcel or Puraflo.
WARRANTIES
Most Tricel products have a warranty. To discover all the guarantees on our products, as well as on the internal parts, consult our dedicated product pages.
WHAT IS THE QUALITY OF THE WASTEWATER PRODUCED?
The required standards are 20:30:20 BOD, SS, NH4. All Tricel produces exceed the requirements when tested to En12566-3 and comply with SR66.
Learn more about our certification
MAINTENANCE ON THE WASTEWATER TREATMENT SYSTEMS
Tricel recommends that you maintain your device to the fullest. You are obliged by law to avoid all types of pollution or nuisances. Do not hesitate to contact us for more information on our service contracts. An annual maintenance contract may be offered.
Get in touch
Error: Contact form not found.