WASTEWATER TREATMENT
Wastewater Components and Accessories
OVERVIEW
Wastewater components and Accessories by Tricel. We offer a range of different types of accessories or spare parts for our wastewater treatment solutions.
- Distributions boxes
- Turret risers
- Spare lids and covers
See below more information for each.
To book a service for your Tricel wastewater treatment solution, please contact us and we will refer you to our distributor in your area.
In this page :
Table of Contents
If you have any questions, feel free to call us
vISIT OUR virtual SHOWROOM
Distributions boxes : Wastewater components
Distribution boxes are used to help distribute pre-treated effluent evenly into drainage trenches or soakaways. Our distribution boxes are gravity fed. They connect to a septic tank or wastewater treatment plant and distribute the pre-treated effluent to the drainage fields/soakaways.
Specifications:
- Constructed from durable thermoplastic material
- Manhole Cover included
- Dimensions (LxWxH) 350x350x450mm
- Manhole Diameter 300mm
- Complete with six access points and is suitable for use with a 4″ pipe, compatible with 110 pipe.
Distribution boxes are available for:
Turret risers
Risers are available and used for deeper installations. When a septic tank or wastewater treatment plants has to be installed at a deeper depth, risers are available to provide access for desludging and maintenance of the systems in place.
Risers are available for:
They are easy to install (see below for more information) and give the flexibility to adapt to the site requirements and deep excavations.
Risers for Tricel Vento Septic Tank
Manhole risers are available for deeper installation requirements. They are available in 180mm increments x 400mm diameter to a maximum height of 540mm (max 3 risers). All manhole lids are securable and must be secured for safety and to prevent unauthorised access. All maintenance work is done through these manholes. Please refer to the manual (section 8) for more information about the risers and their installations.
Please note that 2 risers are required for each septic tank
Distribution box risers are also available.
They increase the height of the distribution box by 225mm. A maximum of 3 risers is permitted with every distribution box.
Tricel Novo risers for deep installation
Tricel offers three different manhole riser heights to suit different invert/inlet levels. Manhole risers allow for the positioning of the treatment plants at the depth which is optimum to each individual installation. Wastewater is gravity fed from the home to your treatment plant.
The inlet pipe’s position from the premises determines the excavation depth for the wastewater treatment plant. Tricel offers a choice of manhole risers 250mm/500mm/750mm to help with installation where site conditions require a flexible solution.
Please note that the Novo comes with a 250mm riser piece, 110mm pipe, clear braided hose, assorted bolts and hose clips.
The quantity of risers required varies according to which Tricel Novo IRE model you have and the number of turrets that need extending. For example: a Tricel IRE6 has x1 turret and will require only x1 riser whereas a Tricel IRE50 has x7 turrets and will therefore require x7 riser
For more information about the installation of the risers, please refer to the Tricel Novo Manual (5.9 “Risers”).
Turret Riser Installation for Tricel Novo wastewater treatment plants
The main reason for a riser to be used is when the waste pipe from the dwelling is lower than the inlet on the Novo wastewater treatment plant which is at 535mm. The installer can lower by an additional 750mm on top of the 535mm.
Manhole risers are available to facilitate this and to avoid the access hatch being positioned in a depression, as shown in the diagram.
NOTE: All installation work to be carried out by a trained competent person. We recommend you also download and read the manual.
Caution: Always isolate electricity before commencing any installation
Desludging cover installation
Steps to follow:
- Take off the desludging cover.
- Apply a bead of silicone around the insides of both sides of the joiner to seal.
- Put the joiner on the pipe already in place.
- Put extension in place.
- Apply another bead of silicone to the outside of the joiner to ensure a watertight seal.
- Place desludging cover onto pipe as before.
Turret riser Installation
See below the steps to follow:
- Take off access cover. Disconnect any electrics or pipework if necessary.
- Apply a bead of silicone around the inside curved flange edge of the first riser.
- Place the riser flange down on the turret.
- Secure the riser in place using 8 M6 x 25mm tech screws. Insert screw at 90-degree angle.
Where more than a 250mm rise is required
- Apply a bead of silicone all around the top edge of the riser.
- Place another 250mm riser in position on top of the first riser.
- Repeat steps 5 and 6 for a 750mm rise.
- Secure the riser in place using 8 M6 x 25 tech screws. Insert screws at a 45-degree angle.
- Apply a bead of silicone on the inside of the riser to the riser joint. Make sure a good watertight seal is achieved.
- Place the access cover back in position and reconnect any electrics.
- Secure access in position using M12 bolt.
Each lid should be secured at all times to prevent unauthorised access. Tanks are supplied with two securing points, as shown below.
To secure the lid, rotate until tight. Tighten the screws in place with a screwdriver. The lid is now secured in place.
Why does this need to be taken into consideration?
A riser is used, as mentioned previously when the waste pipe from the dwelling is below the inlet of the Novo wastewater treatment plant.
Risers prevent surface ground and water from entering the tank and overloading the system, inhibiting bacteria growth and reducing effluent quality. Furthermore, ground and water entering the blower housing can damage the control panel and the air blower.
Risers on a Tricel wastewater treatment plant
Wastewater components and Accessories: Lids and Covers
Because accidents can happen and the lid or covers of your wastewater treatment plant or septic tank might get damaged and needs replacing.
Please see below the replacement parts, lids and covers for both Tricel Novo and Tricel Vento.
- Access lid for Vento 6, 12, 20 (same lid for all tanks)
- Access lid/cover for Novo UK (will vary depending on the Novo models)
- Blower housing lid for Novo UK (same for all the Novo models)
- Desludge lid for Novo UK (same for all the Novo models)
- Manway risers 250mm, 500mm or 750mm
For all other maintenance and repairs, we would advise you to book in a service.
We would also advise regular maintenance and desludging of your sewage systems to ensure a longer life span of your sewage treatment system.
Articles you might be interested in
Our range of products
Tricel Vento Septic Tank
Shallow dig tank, strong & robust underground tank, No electrical or moving parts. Ideal for sites with good drainage & plenty of space.
Tricel Novo Sewage Treatment Plant
Durable & long lasting SMC tank, shallow dig tank, easy installation (Plug and Play), long life components.
Tricel Maxus Sewage Treatment Plant
Commercial plant. Submerged Aerated Filter (SAF) technology. Ideal for project over 50 PE.
Tricel Tero Tertiary Treatment
An eco-friendly and modular system with proven E.Coli Treatment capabilities in line with the new EPA requirements.
Tricel Puraflo Secondary treatment plant
Ideal for sensitive sites, compliant to Irish Standard, small footprint.
Tricel Sandcel
Sand Polishing Filter
Provides a dual function of polishing the effluent from a wastewater treatment system and disposing it into groundwater.
Tricel Pumping Stations
Pump fluids from one place to another where gravity drainage cannot be used, easy and trouble-free installation
Quality
WHY CHOOSE US
Because Tricel manufactures and chooses the best materials for the design of its products. Most Tricel products have warranties of up to 10 years guarantee. All our products within this product range is CE certified to EU safety, health and environmental requirements.
Please find below the list of our products and the warranty that is applied. Note that this warranty is only valid if the sewage system is properly installed by a qualified installer. Please also know that all warranties are subject to correct use of the product, including maintenance as per manufacturer guidelines.
Key features
Fast delivery
Partners network
Technical expertise
50 YEARS IN BUSINESS
A highly successful multinational corporation with over 50 years’ valuable industry experience
SEWAGE TREATMENT PLANTS
Plants available for all capacities, from 1PE up to 50PE. Free advice on request.
Fast Delivery
On-time delivery is a core requirement of our successful business operations
Recent projects with Tricel Novo IE6 treatment plant
Extensive industry experience, manufacturing since 1973.
Tricel manufacture deliver & install sewage treatment plants across a wide range of industry sectors throughout Ireland & the UK. Tricel also provide import/export services for our international clients. Top quality material offers outstanding capabilities including long life, durability and is a cost-effective solution for sewage treatment even in the harshest environments.
Tricel has installed many of its Tricel Novo Sewage Treatment Plants across the UK.
Frequently Asked Questions
WHAT IS PE ?
PE represents the initials of Population Equivalent. Population equivalent: conversion value which aims at expressing non-domestic applications in terms of domestic loading based on 1 person creates 60 g/day BOD5 and 150l/day. (Code of Practice: Wastewater Treatment and Disposal Systems Serving Single Houses (p.e. < 10), EPA)
DIFFERENT PRODUCTS SOLD BY TRICEL
Tricel Novo & Vitae
Both are wastewater treament plant solutions manufactured by Tricel. Wastewater treatment plants offer a superior quality of treatment. For example, the Tricel Novo comprises of three independent wastewater treatment zones and offers an average of efficiency of 95.9% BOD removal.
This is a higher treatment standard than the effluent from a septic tank. Please note: all wastewater treatment plants used in Ireland must comply with the EN12566-3 standard and all septic tanks must comply with the EN12566-1 standard..
Tricel Vento
The septic tank from Tricel is manufactured as a primary treatment. Designed for the settlement of your effluent. This product may need an additional treatment like the Sandcel or Puraflo.
WARRANTIES
Most Tricel products have a warranty. To discover all the guarantees on our products, as well as on the internal parts, consult our dedicated product pages.
WHAT IS THE QUALITY OF THE WASTEWATER PRODUCED?
The required standards are 20:30:20 BOD, SS, NH4. All Tricel produces exceed the requirements when tested to En12566-3 and comply with SR66.
Learn more about our certification
MAINTENANCE ON THE WASTEWATER TREATMENT SYSTEMS
Tricel recommends that you maintain your device to the fullest. You are obliged by law to avoid all types of pollution or nuisances. Do not hesitate to contact us for more information on our service contracts. An annual maintenance contract may be offered.
Get in touch
Error: Contact form not found.