Spare Parts and Accessories

Distribution boxes, risers and lids

Tricel Environment Ireland carries a range of wastewater treatment plants and septic tank parts and accessories to work with the Tricel Vento septic tank and Tricel Novo sewage treatment plant.

Spare Parts and Accessories

Wastewater Treatment Spare Parts and Accessories

Overview

Wastewater Treatment Spare Parts and Accessories by Tricel. We offer a range of different types of accessories or spare parts for our wastewater treatment solutions. 

  1. Distributions boxes
  2. Turret risers
  3. Spare lids and covers

See below more information for each. 

To book a service for your Tricel wastewater treatment solution, please contact us and we will refer you to our distributor in your area.

Tero Tertiary Product

Distributions boxes for septic tanks and wastewater treatment plants

Distribution boxes are used to help distribute pre-treated effluent evenly into drainage trenches or soakaways. Our distribution boxes are gravity fed. They connect to a septic tank or wastewater treatment plant and distribute the pre-treated effluent to the drainage fields/soakaways.

Specifications:

  • Constructed from durable thermoplastic material
  • Manhole Cover included
  • Dimensions (LxWxH) 350x350x450mm
  • Manhole Diameter 300mm
  • Complete with six access points and is suitable for use with a 4″ pipe, compatible with 110 pipe.

 

Distribution boxes are available for: 

Turret risers

Risers are available and used for deeper installations. When a septic tank or wastewater treatment plants has to be installed at a deeper depth, risers are available to provide access for desludging and maintenance of the systems in place. 

Risers are available for:

They are easy to install (see below for more information) and give the flexibility to adapt to the site requirements and deep excavations. 

Risers for Tricel Vento Septic Tank

Manhole risers are available for deeper installation requirements. They are available in 180mm increments x 400mm diameter to a maximum height of 540mm (max 3 risers). All manhole lids are securable and must be secured for safety and to prevent unauthorised access. All maintenance work is done through these manholes. Please refer to the manual (section 8) for more information about the risers and their installations.

 

Tricel Vento septic tank without risers
Tricel Vento septic tank with risers
Riser for Tricel Vento

Please note that 2 risers are required for each septic tank

Distribution box risers are also available.

They increase the height of the distribution box by 225mm. A maximum of 3 risers is permitted with every distribution box.

Tricel Novo risers for deep installation

Tricel offers three different manhole riser heights to suit different invert/inlet levels. Manhole risers allow for the positioning of the treatment plants at the depth which is optimum to each individual installation. Wastewater is gravity fed from the home to your treatment plant. 

The inlet pipe’s position from the premises determines the excavation depth for the wastewater treatment plant. Tricel offers a choice of manhole risers 250mm/500mm/750mm to help with installation where site conditions require a flexible solution.

Please note that the Novo comes with a 250mm riser piece, 110mm pipe, clear braided hose, assorted bolts and hose clips.

The quantity of risers required varies according to which Tricel Novo IRE model you have and the number of turrets that need extending. For example: a Tricel IRE6 has x1 turret and will require only x1 riser whereas a Tricel IRE50 has x7 turrets and will therefore require x7 riser

For more information about the installation of the risers, please refer to the Tricel Novo Manual (5.9 “Risers”).

Turret Riser Installation for Tricel Novo wastewater treatment plants

The main reason for a riser to be used is when the waste pipe from the dwelling is lower than the inlet on the Novo wastewater treatment plant which is at 535mm. The installer can lower by an additional 750mm on top of the 535mm.
Manhole risers are available to facilitate this and to avoid the access hatch being positioned in a depression, as shown in the diagram.

NOTE: All installation work to be carried out by a trained competent person. We recommend you also download and read the manual.

Caution: Always isolate electricity before commencing any installation

Turret Riser wastewater treatment

Desludging cover installation

Steps to follow:

  1. Take off the desludging cover.
  2. Apply a bead of silicone around the insides of both sides of the joiner to seal.
  3. Put the joiner on the pipe already in place.
  4. Put extension in place.
  5. Apply another bead of silicone to the outside of the joiner to ensure a watertight seal.
  6. Place desludging cover onto pipe as before.
Desludging cover

Turret riser Installation

See below the steps to follow:

  1. Take off access cover. Disconnect any electrics or pipework if necessary.
  2. Apply a bead of silicone around the inside curved flange edge of the first riser.
  3. Place the riser flange down on the turret.
  4. Secure the riser in place using 8 M6 x 25mm tech screws. Insert screw at 90-degree angle.
Turret riser Installation

Where more than a 250mm rise is required:

  1. Apply a bead of silicone all around the top edge of the riser.
  2. Place another 250mm riser in position on top of the first riser.
  3. Repeat steps 5 and 6 for a 750mm rise.
  4. Secure the riser in place using 8 M6 x 25 tech screws. Insert screws at a 45-degree angle.
  5. Apply a bead of silicone on the inside of the riser to the riser joint. Make sure a good watertight seal is achieved.
  6. Place the access cover back in position and reconnect any electrics. 
  7. Secure access in position using M12 bolt.

 

Secure Riser To Turret

Each lid should be secured at all times to prevent unauthorised access. Tanks are supplied with two securing points, as shown below.

To secure the lid, rotate until tight. Tighten the screws in place with a screwdriver. The lid is now secured in place.

Why does this need to be taken into consideration? 

A riser is used, as mentioned previously when the waste pipe from the dwelling is below the inlet of the Novo wastewater treatment plant.

Risers prevent surface ground and water from entering the tank and overloading the system, inhibiting bacteria growth and reducing effluent quality. Furthermore, ground and water entering the blower housing can damage the control panel and the air blower.

Risers on a Tricel Novo wastewater treatment plant in Limerick (before and after)

Novo tank in limerick before
Novo tank in limerick
risers on a Novo tank in limerick
risers on a Novo tank in limerick

Wastewater Treatment Spare Parts and Accessories: Lids and Covers

Because accidents can happen and the lid or covers of your wastewater treatment plant or septic tank might get damaged and needs replacing.

Please see below the replacement parts, lids and covers for both Tricel Novo and Tricel Vento. 

  • Access lid for Vento 6, 12, 20 (same lid for all tanks)
  • Access lid/cover for Novo UK (will vary depending on the Novo models)
  • Blower housing lid for Novo UK (same for all the Novo models)
  • Desludge lid for Novo UK (same for all the Novo models)
  • Manway risers 250mm, 500mm or 750mm 

 

For all other maintenance and repairs, we would advise you to book in a service.

We would also advise regular maintenance and desludging of your sewage systems to ensure a longer life span of your sewage treatment system.

 

View the manuals & brochures

Get a Quote and Order your spare parts

Key Features

Fast delivery

Fast delivery

Fast delivery and rapid response to all of our customers.

Partner network

Partners network

Combined knowledge of service partner network throughout Europe.

Technical expertise

Technical expertise

Unrivalled technical expertise in the installation, commissioning and maintenance of wastewater treatment solutions.

Frequently asked questions

FAQs

Different products sold by Tricel

Tricel Novo & Vitae: Both are wastewater treament plant solutions manufactured by Tricel. Wastewater treatment plants offer a superior quality of treatment. For example, the Tricel Novo comprises of three independent wastewater treatment zones and offers an average of efficiency of 95.9% BOD removal.
This is a higher treatment standard than the effluent from a septic tank. Please note: all wastewater treatment plants used in Ireland must comply with the EN12566-3 standard and all septic tanks must comply with the EN12566-1 standard..

Tricel Vento: The septic tank from Tricel is manufactured as a primary treatment. Designed for the settlement of your effluent. This product may need an additional treatment like the Sandcel or Puraflo.

Certifications for Tricel wastewater treatment systems

The Tricel wastewater treatment plants comply with the European Standard EN12566, S.R. 66, and with the Environmental Protection Agency (EPA) Code of Practice. Click below for more details about the certifications.

Get in touch


    Type of request*

    Are you a*

    Your enquiry is for*


    HQ

    Tricel (Killarney) Unlimited Company
    Ballyspillane Industrial Estate, Killarney, Co. Kerry, V93 X253, Ireland
    Tel: 64 663 2421