Overview
The Tricel Maxus operates on Submerged Aerated Filter (SAF) Technology. The Plant is controlled by the E-III control panel through which all electrical components are connected.
They are robust and easy to install, with multiple configurations that suit any site.
Simple in operation, they are easy to maintain over the product’s lifespan.
Applications include:
- hotels
- schools
- factories
- housing estates
- nursing homes
- garden centres
- petrol stations
- restaurants
- caravan parks and campsites
- retail units
to name a few.
These highly versatile systems are individually sized to suit every scenario over 50PE.
KEY FEATURES AND BENEFITS OF THE TRICEL MAXUS WASTEWATER TREATMENT
Wastewater treatment is suitable for more than 50 Population Equivalent (PE) applications.
- Excellent treatment from proven SAF technology.
- Ideal for seasonal loads or constant loads. The control panel will automatically adjust to the incoming load to ensure optimum performance.
- Extensively tested and ETA verified for holiday home applications. The system will go into a power-saving mode during periods of no flow and restart once a flow is detected without the need for any manual inputs.
- Swift back up and service located in Ireland. Range of service contracts available.
- Full design engineered solutions are offered. Bespoke solutions are offered for every unique site to ensure the best performance. GRP or Concrete settlement tank options.
- Flexible installation options to suit any site. This plant can fit into difficult sites or simply save space.
- Versatile technology which can adapt to different loadings or effluent strengths.
- Simple operation using long-life reliable components leads to low running costs. No moving parts within the plant make it easy to maintain.
How does the Tricel Maxus work?
The wastewater treatment Tricel Maxus utilizes highly effective SAF technology, treating wastewater in 4 stages.
1. The settlement tank:
Wastewater enters into the Tricel Maxus System in the settlement tank. Here, primary treatment occurs. Heavy solids are separated from the wastewater and settle out to form a sludge on the tank’s base. Lighter solids, such as oil fats, or grease, float to the top of the wastewater and are retained within the settlement tank.
2. The buffer tank:
From here, the partially treated wastewater enters the buffer tank. The buffer tank will even out any fluctuations in the incoming water load. Pumps at the buffer tank’s bottom feed the wastewater into the treatment plant.
3. The biological treatment zone:
In this zone, the submerged aerated filter, with a large surface area for the microbes, is exposed to heavy aeration as the wastewater passes through. The system will never clog and does not need any maintenance or chemicals.
4. The clarifier:
In the clarifier, bio sludge from the treatment process settles out of the treated liquid. Airlift pumps recirculate the bio sludge from the base of the tank back to the settlement tank. The fully treated liquid is now ready to discharge from the plant.
The settlement and buffer tanks
The settlement and buffer tanks
Technical Characteristics and Plant Dimensions
The table below shows Tricel Maxus system sizes, but each system is designed to suit project requirements.
Code | PE | Settlement And Buffer Tank* (1+2) | Treatment Plant (3+4) | ||||||
---|---|---|---|---|---|---|---|---|---|
Tank | L (M) | W (M) | H (M) | Plant shape** | L (M) | W (M) | H (M) | ||
66M5000 | 66 | Settlement | 6.60 | 1.64 | 2.05 | Circular | 2.00 | 2.00 | 2.20 |
Buffer | 1.60 | 1.64 | 2.05 | ||||||
88M6000 | 88 | Settlement | 6.60 | 1.64 | 2.05 | Circular | 2.30 | 2.30 | 2.20 |
Buffer | 3.60 | 1.64 | 2.05 | ||||||
112J25 | 112 | Settlement | 6.60 | 1.64 | 2.05 | Rectangular | 2.80 | 2.16 | 2.22 |
Buffer | 6.60 | 1.64 | 2.05 | ||||||
154J50 | 154 | Combined | 5.70 | 2.87 | 2.70 | Rectangular | 3.30 | 2.16 | 2.22 |
175J75 | 175 | Combined | 6.17 | 2.87 | 2.70 | Rectangular | 3.95 | 2.16 | 2.22 |
238J100 | 238 | Combined | 9.05 | 2.87 | 2.70 | Rectangular | 5.45 | 2.16 | 2.22 |
294J50X2 | 294 | Combined | 10.89 | 2.87 | 2.70 | Rectangular | 6.60 | 2.16 | 2.22 |
285J75X2 | 385 | Combined | 14.12 | 2.87 | 2.70 | Rectangular | 7.90 | 2.16 | 2.22 |
560J100X2 | 560 | Settlement | 9.95 | 2.87 | 2.70 | Rectangular | 10.90 | 2.16 | 2.22 |
Buffer | 9.95 | 2.87 | 2.70 |
*All settlement and buffer tank dimensions are for GRP tanks as standard. Concrete options are available.
** Please note, the treatment plant is circular for up to 88PE and rectangular for plants over 88PE.
Tricel Maxus brochure
Tricel Maxus wastewater treatment systems installed
Tricel Maxus circular shape
An installation with combined GRP Settlement and buffer tanks.
Tricel Maxus circular shape
Wastewater Treatment plant during installation.
Tricel Maxus circular shape
Remote settlement and buffer tanks to suit a site with restricted space.
Tricel Maxus rectangular shape
An installation with combined GRP Settlement and buffer tanks.
Tricel Maxus rectangular shape
Wastewater Treatment plant during installation.
Tricel Maxus rectangular shape
Finished Tricel Maxus installation with separate concrete settlement and buffer tanks.
FAQ – Tricel Maxus Wastewater Treatment Plant
Can the Tricel Maxus adapt to different loadings or effluent strengths?
Yes, we have a solution for everything. We can work with BOD load high or low and find suitable options for your site.
The versatile technology can be adapted to different loadings or effluent strengths. With its flexible design, we can easily add more treatment zones and clarifiers to ensure the effluent meets site requirements (such as low BOD, nitrogen, phosphorus, or even E-coli).
Does Tricel offer design/bespoke solutions?
Yes. We work with you to offer a bespoke solution for your unique site to ensure the best performance.
Contact us to discuss your project and requirements.
Some of the questions we’ll cover with you:
- Where are you discharging? You might also need extra such as Sandcel sand polishing filter or Tricel Puraflo.
- What is your effluent quality requirement?
- Sizing the plant
- What is in the effluent (standard or unusual -> lots of washing machines for example)?
- Futureproofing
What is the Maxus running efficiency?
The Maxus is suitable for both seasonal or constant load. The control panel automatically adjusts as incoming loads increase to ensure optimal performance. By working with the flow, the pumps on the tank reduce energy costs during off-peak seasons.
Ideal for:
- Schools (opened 5 days/week and closed during holidays)
- Hotels (busy during summers, closed during winters)
- Housing estates (where the theoretical PE calculation might be higher than the actual load)
Does the Tricel Maxus allow for population extension / futureproofing?
Yes. Let’s take an example of a hotel with a requirement of 100 PE and futureproofing for 200 PE in a few years’ time.
In this case, we would do the following:
- Settlement tank (1) and buffer tank (2) for 200 PE
- Biological treatment zone (3) and clarifier (4) for 100 PE. The extra cost would be only for an additional 3+4 when required.
Key Features
Proven SAF technology
The Tricel Maxus operates on Submerged Aerated Filter Technology (SAF).
Swift back up and service
We are located in Ireland.
Versatile technology
Can adapt to different loadings or effluent strengths.
Get in touch
HQ
Tricel (Killarney) Unlimited Company
Ballyspillane Industrial Estate, Killarney, Co. Kerry, V93 X253, Ireland
Tel: 64 663 2421