SEWAGE TREATMENT
Biocycle unit equivalent : The Tricel Novo
Home » Wastewater Treatment » Biocycle unit
- May 29, 2025
Table of Contents
If you have any questions, feel free to call us
vISIT OUR virtual SHOWROOM
looking for a Biocycle Unit?
If you’re exploring options for a biocycle unit, the Tricel Novo is a high-quality alternative worth considering. This compact wastewater treatment plant is efficient, durable, easy to install, and simple to maintain—making it ideal for both new builds and system upgrades.
Unlike traditional septic tanks, the Tricel Novo offers advanced treatment performance while remaining cost-effective and reliable. Tested to EN12566-3 standards, it ensures compliance with Irish environmental regulations and delivers consistently clean effluent.
Whether you’re replacing an existing biocycle unit or planning a new installation, the Tricel Novo provides a practical and long-lasting solution.
Need advice on your project? Contact our technical and sales team today—we’re here to help.
How does the biocycle unit by Tricel work?
Tricel Novo has a 3 stages:
Stage 1: the primary settlement chamber
On the first stage of wastewater treatment, the grease and solids are separated from the water. The grease will stay on the surface and the solids will go to the bottom of the tank.
Stage 2: the aeration chamber
In this compartment, the wastewater treatment involves aerobic breakdown. Masses of naturally occurring bacteria inhabit specially designed filter media.
The aerobic bacteria is going to digest the pollution from the wastewater. This bacteria is sustained with air, which is continuously supplied from a purpose-built pump in the unit’s top section.
Stage 3: final settlement chamber
In the third stage of wastewater treatment, the suspended sludge containing bacteria is carried with the liquid into the settlement chamber and settles to the bottom of the chamber.
From there, a continuous sludge return system pumps it back to the primary settlement chamber. The remaining treated liquid now meets the required standard to be safely passed out of the Tricel system.
Features and Benefits of the Tricel wastewater treatment plant
- Compression moulded SMC tank. SMC is exceptional in the wastewater treatment industry, with Tricel SMC tanks operating in some of the harshest climatic conditions for over 50 years with no defects.
- Components are manufactured under heat and high pressure and have unparalleled strength and toughness over standard GRP tanks or PE tanks.
- Tricel’s ceramic diffuser is a first in the domestic wastewater treatment industry and will last twice as long as all standard competitors’ rubber equivalents. This saves money in both call-out fees and replacement parts.
- No concrete backfill for installation on most sites, saving up to €400 over lower quality GRP/plastic competitors.
- No moving parts or pumps in the plant, ensuring consistent operation and minimal maintenance and repair costs.
- Tricel Novo plants are designed with a shallow invert to reduce both installation and time costs.
The size of your Tricel Novo unit
This is a crucial step, as choosing the correct size goes hand in hand with the overall efficiency of the treatment system. Without proper sizing, a domestic wastewater treatment system may fail to function effectively. As a result, the effluent can contaminate the local environment, leading to serious consequences such as damaged wells, polluted water sources, and broader public health issues.
How to Determine the Size of Your System?
To size a residential wastewater treatment system accurately, the most commonly used metric is the Population Equivalent (PE).
In simple terms, PE represents the load a system must handle, based on the wastewater typically produced by one person. According to the OECD, population equivalent refers to the amount of oxygen-demanding substances that, during biodegradation, consume as much oxygen as the wastewater produced by one individual.
For calculation purposes, one PE is generally considered to equal 54 grams of BOD (Biological Oxygen Demand) per 24 hours.
So, how do you calculate the PE for your home?
In most cases, the PE value is based on the number of bedrooms in the house. The more bedrooms you have, the greater the expected occupancy, and therefore, the higher the wastewater load.
To help guide you, the table below outlines the typical PE range based on bedroom count:
Number of bedrooms | Population Equivalent (PE) |
---|---|
2 | 4 |
3 | 5 |
4 | 6 |
5 | 7 |
6 | 8 |
7 | 9 |
8 | 10 |
Tricel Novo Range
Design population | IE6 | IE8 | IE10 | IE12 | IE18 | IE24 | IE30 | IE36 | IE42 | IE50 |
---|---|---|---|---|---|---|---|---|---|---|
Number of people | 1-6 | 2-8 | 3-10 | 4-12 | 6-18 | 8-24 | 10-30 | 12-36 | 14-42 | 16-50 |
Dimensions of the Tricel Novo
Tricel Novo IE6
No of people: 1-6
Length: 2.10m
Width: 1.64m
Height: 2.24m
Air blower rating: 60 watts
Tricel Novo IE12
No of people: 4-12
Length: 3.60m
Width: 1.64m
Height: 2.27m
Air blower rating: 100 watts
Tricel Novo IE36
No of people: 12-36
Length: 3.60m
Width: 1.64m
Height: 1.99m
Length: 5.60m
Width: 1.64m
Height: 2.27m
Air blower rating: 200 watts + 800 watts
Tricel Novo IE6+
No of people: 2-6
Length: 2.60m
Width: 1.64m
Height: 2.24m
Air blower rating: 60 watts
Tricel Novo IE18
No of people: 6-18
Length: 4.60m
Width: 1.64m
Height: 2.27m
Air blower rating: 200 watts
Tricel Novo IE42
No of people: 14-42
Length: 5.60m
Width: 1.64m
Height: 2.27m
Length: 5.60m
Width: 1.64m
Height: 2.27m
Air blower rating: 200 watts x 2
Tricel Novo IE8
No of people: 2-8
Length: 2.60m
Width: 1.64m
Height: 2.24m
Air blower rating: 80 watts
Tricel Novo IE24
No of people: 8-24
Length: 6.60m
Width: 1.64m
Height: 2.27m
Air blower rating: 200 watts
Tricel Novo IE50
No of people: 16-50
Length: 6.60m
Width: 1.64m
Height: 2.27m
Length: 6.60m
Width: 1.64m
Height: 2.27m
Air blower rating: 200 +120 + 80 watts
Tricel Novo IE10
No of people: 3-10
Length: 3.10m
Width: 1.64m
Height: 2.24m
Air blower rating: 80 watts
Tricel Novo IE30
No of people: 10-30
Length: 2.60m
Width: 1.64m
Height: 1.99m
Length: 5.60m
Width: 1.64m
Height: 2.27m
Air blower rating: 200 watts + 800 watts
IE Pumped Outlet
1-6 domestic pumped unit. Suitable for pumping to a raised discharge area (over).
Tricel Novo: Key features & benefits
The compression moulding process is one of the most technologically advanced features available on the market. Components are manufactured under heat and high pressure. They have a competitive strength and durability over standard GRP tanks or PE tanks.
SMC is a unique material in the sewage treatment industry with Tricel SMC tanks operating in some of the harshest climatic conditions for over 50 years with no defects.
Tricel’s ceramic diffuser will last twice as long as all standard competitors rubber equivalents. It is a cost-saver in both call out fees and replacement parts.
No concrete backfill for installation on most sites which allows you to save up to €400 over lower quality GRP/plastic competitors.
There are no moving parts or pumps in the plant which is ensuring reliable operation during the treatment process and minimal running costs.
Tricel Novo plants are designed with a shallow invert to limit both installation and time costs.
You might also be interested in
- Wastewater Treatment
Our range of products
Tricel Vento Septic Tank
Shallow dig tank, strong & robust underground tank, No electrical or moving parts. Ideal for sites with good drainage & plenty of space.
Tricel Novo Sewage Treatment Plant
Durable & long lasting SMC tank, shallow dig tank, easy installation (Plug and Play), long life components.
Tricel Maxus Sewage Treatment Plant
Commercial plant. Submerged Aerated Filter (SAF) technology. Ideal for project over 50 PE.
Tricel Tero Tertiary Treatment
An eco-friendly and modular system with proven E.Coli Treatment capabilities in line with the new EPA requirements.
Tricel Puraflo Secondary treatment plant
Ideal for sensitive sites, compliant to Irish Standard, small footprint.
Tricel Sandcel
Sand Polishing Filter
Provides a dual function of polishing the effluent from a wastewater treatment system and disposing it into groundwater.
Tricel Pumping Stations
Pump fluids from one place to another where gravity drainage cannot be used, easy and trouble-free installation
50 YEARS IN BUSINESS
A highly successful multinational corporation with over 50 years’ valuable industry experience
SEWAGE TREATMENT PLANTS
Plants available for all capacities, from 1PE up to 50PE. Free advice on request.
Fast Delivery
On-time delivery is a core requirement of our successful business operations
Meet our team
To find a technician in your area, visit our page
TALK SEWAGE TREATMENT
To speak to one of our agents online, click here
ASK FOR A QUOTE
Request a free quote today to have a quote that meets your project!
Key Features
RELIABLE & LONG-LASTING
SMC tank, strong & lightweight
FAST DELIVERY
Tricel Products are certified to EN12566-1 and EN 12566-3 certified
CERTIFIED
Get in touch
Error: Contact form not found.